*All
hoses are tested at 11/2
times rated working pressure for safety
and reliability, in accordance with BS 5842;1980
clause 6.4.Full test certification
can be supplied on request,
issued in our laboratories, or witnessed
form independent third part Institutes.
*Hoses are designed, for type
approval, to a burst pressure 5 time the W.P.
Burst pressure indicated, is
at ambient temperature when
tested in accordance with BS 5173 section
102.10.1990.
*Electrical
continuity is achieved by
the two wires bonded
to the end fittings, this helps dissipate
accumulated charge and to avoid
static flash. The electric resistance
of hose assemblies is less than 10 ohms,
as required by BS 5842:1980
clause 6.2. Hose assemblies
can also be provided, on request,
electrically discontinuous.
*It
is possible, on request, to
offer a range of hoses with fire and
flame resistance CL 1, please contact
COMPOTEC® Technical Department
for further information.
|